Bullet-resistant glazing is specified against a defined ballistic test requirement, not by an ordinary laminated-glass thickness alone.
Required protection: State the test standard, edition and performance designation.
Total thickness: Determined by the proposed tested construction.
Opening example: 1000 × 1200 mm quotation opening.
Send drawings, quantities and destination details for a project quotation.
Required protection: State the test standard, edition and performance designation. For example, identify the applicable UL 752 edition rather than assuming ratings from different editions are interchangeable.
Total thickness: Determined by the proposed tested construction. No generic millimetre value or ordinary laminate is offered here as a ballistic rating.
Opening example: 1000 × 1200 mm quotation opening. Enquiry example only; tested product and assembly limits control permitted size.
Construction: Glass or composite build-up according to the applicable report. Confirm material sequence, protected face, orientation and any edge restrictions.
Framing and interfaces: Frame, retainers, fixings and any transaction opening. Review the complete specified assembly and installation requirements.
Bullet-resistant glazing is specified against a defined ballistic test requirement, not by an ordinary laminated-glass thickness alone. The term bulletproof glass is commonly used in enquiries, but no glazing is universally proof against every threat. This page supports technical enquiries: availability and any product claim depend on review of the exact tested construction, size range, installation details and supporting report.
![]()
Illustrative product concept and material details; not a completed-project photograph or test evidence. Final construction follows the approved order.
Examples support quotation discussions. Confirm availability, production feasibility and the final specification before ordering.
| Item | Reference specification | What to confirm |
|---|---|---|
| Required protection | State the test standard, edition and performance designation | For example, identify the applicable UL 752 edition rather than assuming ratings from different editions are interchangeable. |
| Total thickness | Determined by the proposed tested construction | No generic millimetre value or ordinary laminate is offered here as a ballistic rating. |
| Opening example | 1000 × 1200 mm quotation opening | Enquiry example only; tested product and assembly limits control permitted size. |
| Construction | Glass or composite build-up according to the applicable report | Confirm material sequence, protected face, orientation and any edge restrictions. |
| Framing and interfaces | Frame, retainers, fixings and any transaction opening | Review the complete specified assembly and installation requirements. |
| Production and documents | Technical approval before production scheduling | Request current report identity, test scope and any relevant listing information. |
Provide the threat specification and required test method through the responsible project consultant. Standard edition and performance designation matter. A nominal thickness, number of panes or marketing description cannot substitute for a test report that applies to the actual proposed product.
The frame, edge support, joints, penetrations and protected-side requirements can affect the installed system. Identify which face is exposed to the threat and whether spall requirements apply. Cut-outs, speaker openings and transaction hardware require explicit review rather than on-site modification.
Ask for the proposed construction and the supporting report or listing relevant to its size and use. A report for another thickness, material sequence or assembly should not be treated as confirmation. No ballistic class, certification or current supply availability is implied solely by this webpage.
Security-glazing production is project-led. Quantities, equipment route, inspection, packing and lead time are confirmed only after the proposed tested build-up and supply scope are accepted. General architectural lamination throughput is not a published ballistic-glazing production capacity.
Identify the protected side and panel orientation on agreed labels. Discuss edge protection, suitable lifting equipment, panel weight and frame compatibility before dispatch. Any requirements from the tested product documentation must be retained during handling and installation.
Send the standard and edition, performance requirement, consultant specification, opening and panel sizes, frame details, quantities, destination and requested documentation. Request technical approval before including a product in the project specification.
Send your specifications to Globalstar Glass for technical and commercial review.
Related products: architectural PVB laminated glass and tempered laminated glass.
Ordinary lamination does not establish ballistic resistance. Use only a construction supported by the required product or assembly evidence.
Only a preliminary enquiry can be discussed. Final construction and thickness depend on the applicable tested specification.
No. Any such claim requires documentation for the exact proposed product and applicable standard edition.
Do not modify a security glazing assembly without explicit approval under its product and installation requirements.
List every component so the quotation and supporting documentation define the complete supply scope.
The company is committed to becoming a global leader in energy-efficient and safe glass manufacturing, contributing to a happier life for humanity and making the world a better place.
Custom PVB laminated glass with clear or coloured interlayers. Review 6.38–17.52 mm reference builds, dimensions, edge details and export packing.
Coloured laminated glass for decorative glazing. Compare tinted glass and coloured PVB, reference build-ups, colour samples and panel layouts.
Discuss bullet-resistant glazing requirements, tested build-ups, thickness, framing and documentation. Request a technical review before specifying a product.
Explore switchable PDLC privacy glass. Review glass build-ups, panel size, controller requirements, clear and translucent states and quotation details.
Custom tempered laminated glass. Review 6+6, 8+8 and 10+10 glass builds, interlayer options, aligned holes, polished edges and export packing.
Fabric laminated glass for decorative interiors. Review textile samples, glass thickness, insert direction, edge details and custom panel layouts.
Glass louver blades for jalousie windows. Review 4–6 mm options, 4-inch and 6-inch reference widths, polished edges, frame compatibility and export packing.
Decorative textured laminated glass for interior projects. Review patterned substrates, glass plies, interlayers, panel layouts and sample approval.
Copyright © 2025 Qingdao Globalstar Glass Technology Co., Ltd. Powered by HiCheng